China FZN25-12D Series High Voltage Vacuum Load Switch - Reliable Suppliers and Factory for 12kV Solutions
Technical Specification
No. |
Item |
Units |
Parameters |
||
FZN25-12D/T630-20 |
FZRN25-12D/T125-31.5 |
||||
1 |
Rated voltage |
kA |
12 |
||
2 |
Rated frequency |
HZ |
50 |
||
3 |
Rated Current |
A |
630 |
125 |
|
4 |
Rated insulation level |
1min frequency voltage |
KV |
Interrupter Fracture 30. On the ground, white 42. Isolation Fracture 48 |
|
Lightning impulse withstand voltage |
KV |
On the ground, white 75. Isolation Fracture 85 |
|||
5 |
Rated dynamic stability current (peak) |
KA |
50 |
- |
|
6 |
4S thermal current |
KA |
20 |
- |
|
7 |
Rated active load breaking current |
A |
630 |
125 |
|
8 |
Rated closed-loop breaking current |
A |
630 |
125 |
|
9 |
Rated cable charging breaking current |
A |
10 |
10 |
|
10 |
Breaking load transformer |
KVA |
1250 |
1250 |
|
11 |
Rated short-circuit breaking current |
KA |
- |
31.5 |
|
12 |
Rated transfer current, rated current transfer |
A |
|
2000 |
|
13 |
Fuse Model |
|
- |
SDLAJ-12 / SFLAJ-12 |
|
14 |
Impact energy output |
J |
- |
2–5 (medium) |
|
15 |
Rated short circuit making current |
KA |
50 |
||
16 |
Ground switch rated dynamic current |
|
50 |
||
17 |
Grounding switch 2S thermal current |
KA |
20 |
||
18 |
Secondary circuit rated voltage |
V |
AC/DC 220 / 110 |
||
19 |
Mechanical life |
Times |
1000 |
||
Product Model
Dimension
Frequently Asked Questions
-
Q1 What is the rated voltage of the FZN25-12D and FZRN25-12D switchgear?Both the FZN25-12D/T630-20 and FZRN25-12D/T125-31.5 models are designed for a rated voltage of 12 kV, making them suitable for medium-voltage distribution systems.
-
Q2 What is the difference in rated current between the two models?The FZN25-12D/T630-20 has a rated current of 630 A, while the FZRN25-12D/T125-31.5 has a rated current of 125 A. The FZRN25 model also includes a fuse combination unit for short-circuit protection up to 31.5 kA.
-
Q3 Does the FZRN25-12D model support short-circuit breaking capability?Yes. The FZRN25-12D/T125-31.5 features a rated short-circuit breaking current of 31.5 kA, achieved through its integrated fuse (SDLAJ-12 / SFLAJ-12), which provides reliable fault interruption in demanding grid environments.
-
Q4 What is the mechanical life expectancy of these switchgear units?Both models are rated for a mechanical life of 1,000 operations, ensuring long-term reliability and reduced maintenance requirements in substation and ring main unit applications.
-
Q5 What secondary circuit voltage does the switchgear support?The secondary circuit supports both AC and DC operating voltages of 220 V and 110 V, providing flexibility for integration with various control and protection relay systems.
-
Q6 What is the lightning impulse withstand voltage level for these units?The lightning impulse withstand voltage is 75 kV to ground and 85 kV across the isolation fracture, ensuring robust insulation performance against transient overvoltages in accordance with standard medium-voltage requirements.