China ZW32-24 Series Outdoor High Voltage Vacuum Circuit Breaker - Reliable Suppliers & Factory for 24kV Solutions
Technical Specification
No. |
Item |
Units |
Parameters |
||
1 |
Rated voltage |
kV |
24 |
||
2 |
Rated frequency |
Hz |
50 |
||
3 |
Rated current |
A |
630 |
1250 |
|
4 |
Rated short-circuit breaking current |
kA |
20 |
25 |
|
5 |
Rated peak withstand current (peak) |
KA |
50 |
63 |
|
6 |
Rated short-circuit closing current (peak) |
kA |
50 |
63 |
|
7 |
Rated short-time withstand current and duration |
kA/s |
20/4 |
25/4 |
|
8 |
Rated operation sequence |
|
O-0.3s-CO-180s-CO |
||
9 |
Mechanical life |
Times |
10000 |
||
10 |
Breaking times of rated short-circuit breaking current |
Times |
20 |
||
11 |
1min power frequency withstand voltage |
(wet) over the ground / interphase / fracture |
kV |
50/65 |
|
(dry) over the ground / interphase / fracture |
65/79 |
||||
Secondary loop |
2 |
||||
12 |
Lighting impulse withstand voltage (peak) Over the ground, interphase / fracture |
kA |
125/145 |
||
13 |
Weight |
kg |
115 |
||
Product Model
Dimension
Frequently Asked Questions
-
Q1 What is the rated voltage of this circuit breaker?The rated voltage of this circuit breaker is 24 kV, making it suitable for medium-voltage power distribution systems operating at that level.
-
Q2 What rated current options are available?This circuit breaker is available in two rated current options: 630 A and 1250 A, allowing it to be selected according to the specific load requirements of your installation.
-
Q3 What is the rated short-circuit breaking current?The rated short-circuit breaking current is 20 kA for the standard version and 25 kA for the enhanced version, ensuring reliable fault interruption under high-fault current conditions.
-
Q4 How many mechanical operations can this circuit breaker perform?The circuit breaker has a mechanical life of 10,000 operations, demonstrating excellent durability and reliability for long-term use in power distribution applications.
-
Q5 What is the rated operation sequence of this product?The rated operation sequence is O-0.3s-CO-180s-CO, which defines the standard opening and closing cycle the breaker can perform without exceeding its thermal and mechanical limits.
-
Q6 What is the lightning impulse withstand voltage of this circuit breaker?The lightning impulse withstand voltage (peak) is 125 kA over the ground and interphase, and 145 kA across the fracture, ensuring robust protection against transient overvoltages and lightning strikes.