Leave Your Message
pro_banner_013
High-Quality ZGS□-12 Combined Transformer from China Suppliers and Factory for Reliable Cable Distribution Networks

High-Quality ZGS□-12 Combined Transformer from China Suppliers and Factory for Reliable Cable Distribution Networks

Introducing the ZGS□-12 Combined Transformer, a state-of-the-art, fully sealed American-style box transformer specifically designed for cable distribution networks in urban and rural settings. As a leading product from China, this transformer integrates advanced high-voltage control, protection, and distribution equipment, making it ideal for flexible ring-main or terminal power supply solutions. Manufactured in our specialized factory, this transformer features low-loss technology and plug-in dry-type fuses to meet various low-voltage feeder demands efficiently. With its compact and fully insulated design, the ZGS□-12 ensures exceptional safety and reliability, positioning it as a top choice among suppliers in the industry

    ⚙️ Product Model
    ZGS□-12 Combined Transformer Product Model
    📊 Performance Parameters of Transformers
    Performance Parameters of 10kV Prefabricated Substation S11, S13, S20 Series Oil-immersed Transformers

    Serial Number

    Rated Capacity (kVA)

    Rated Voltage High Voltage (kV)

    Rated Voltage Low Voltage (kV)

    Tapping Range (%)

    Vector Group Symbol

    No-load Current (%) S9

    No-load Current (%) S10/S11

    Loss (W) No-load S10

    1

    30

    6
    6.3
    10

    0.4
    (0.69)

    ±5
    (±2×2.5)

    Yyn0
    Dyn11

    2.2

    2.0

    2

    50

    2.0

    1.8

    3

    63

    1.9

    1.5

    4

    80

    1.7

    1.2

    5

    100

    1.6

    1.1

    6

    125

    1.5

    1.0

    340

    7

    160

    1.4

    1.0

    400

    8

    200

    1.4

    0.8

    480

    9

    250

    1.2

    0.8

    560

    10

    315

    1.1

    0.7

    670

    11

    400

    1.0

    0.7

    800

    12

    500

    1.0

    0.6

    960

    13

    630

    0.9

    0.6

    1200

    14

    800

    0.8

    0.6

    1400

    15

    1000

    0.7

    0.5

    1700

    16

    1250

    0.6

    0.5

    1950

    17

    1600

    0.6

    0.5

    2400

    Serial Number

    Loss (W) No-load S10

    Loss (W) No-load S11

    Loss (W) Load S9

    Loss (W) Load S10/S11

    Resistance Voltage (%)

    Noise (dB)

    Temperature Rise

    1

    130

    600

    4

    5.5

    Top oil Temperature 60° coil 65°

    2

    170

    870

    3

    200

    1040

    4

    250

    1250

    5

    290

    1500

    6

    270

    1800

    7

    310

    2200

    8

    375

    2600

    9

    455

    400

    3050

    3000

    10

    540

    475

    3650

    3600

    11

    650

    570

    4300

    4200

    12

    775

    680

    5100

    5000

    13

    920

    800

    6200

    6000

    4.5

    14

    1120

    980

    7500

    7400

    15

    1320

    1150

    10300

    9860

    16

    1560

    1360

    12800

    12000

    17

    1880

    1640

    14500

    14000

    📝 Note:

    • According to customer requirements, the high-voltage tap range of the transformer can be designed as ±2×2.5%.

    • According to customer requirements, the low-voltage of the transformer can be designed as 0.69kV.

    Performance Parameters of Load Switch

    Rated Current (A)

    Rated Voltage (kV)

    Impulse Withstand Voltage (kV)

    Power Frequency Withstand Voltage (1min. kV)

    Rated Short-time Withstand Current (kA/s)

    Short-circuit Making Current (kA)

    Peak Withstand Current of Short-time Current (kA)

    Number of Load Operations

    Number of Mechanical Operations

    315

    12

    75

    42

    12.5/2

    31.5

    31.5

    100

    2000

    630

    12

    75

    42

    16/4

    40

    40

    100

    3000

    📐 Dimensions
    ZGS□ Standard Type Dimensions

    Standard Type

    Capacity kVA

    A

    B

    C

    D

    E

    F

    H

    100–250

    1900

    1650

    1250

    650/800

    600

    1410/1560

    1450

    315

    1900

    1650

    1350

    650/800

    650

    1460/1610

    1450

    400–500

    1900

    1750

    1450

    650/800

    650

    1490/1640

    1550

    630

    1900

    1750

    1550

    650/800

    700

    1580/1730

    1550

    800

    1900

    1850

    1550

    650/800

    700

    1640/1790

    1650

    1000

    1900

    1850

    1650

    650/800

    700

    1640/1790

    1650

    ZGS□-12 Combined Transformer Standard Type Dimensions Diagram
    ZGS□ Enhanced Type Dimensions

    Standard Type

    Capacity kVA

    A

    B

    C

    D

    E

    F

    H

    100–250

    2400

    1650

    1250

    800

    600

    1560

    1450

    315

    2400

    1650

    1350

    800

    650

    1610

    1450

    400–500

    2400

    1750

    1450

    800

    650

    1640

    1550

    630

    2400

    1750

    1550

    800

    700

    1730

    1550

    800

    2400

    1850

    1550

    800

    700

    1790

    1650

    1000

    2400

    1850

    1650

    800

    700

    1790

    1650

    ZGS□-12 Combined Transformer Enhanced Type Dimensions Diagram
    ZGS□ Enhanced Type Dimensions (Extended Parameters)

    Standard Type

    Capacity kVA

    A

    B

    C

    D

    E

    F

    G

    M

    H

    100–250

    2400

    1750

    1250

    800

    600

    1750

    1560

    950

    550

    315

    2400

    1750

    1350

    800

    650

    1750

    1610

    950

    550

    400–500

    2400

    1850

    1450

    800

    650

    1750

    1640

    950

    550

    630

    2400

    1850

    1550

    800

    650

    1750

    1720

    950

    550

    800

    2400

    1950

    1650

    800

    650

    1750

    1790

    950

    550

    1000

    2400

    1950

    1650

    800

    700

    1750

    1840

    950

    550

    ❓ Frequently Asked Questions (FAQ)
    Q What is the ZGS□-12 Combined Transformer used for?
    The ZGS□-12 Combined Transformer is designed for use in 10kV prefabricated substations. It integrates the transformer with high-voltage switchgear and low-voltage distribution equipment into a compact unit, making it suitable for urban power distribution, industrial facilities, and commercial buildings.
    Q What capacity range is available for the ZGS□-12 Combined Transformer?
    The ZGS□-12 Combined Transformer is available in a wide range of rated capacities from 30 kVA up to 1600 kVA, covering the S9, S10, S11, S13, and S20 series oil-immersed transformer types to meet various application requirements.
    Q Can the high-voltage tap range be customized?
    Yes. According to customer requirements, the high-voltage tap range of the transformer can be designed as ±2×2.5%, providing greater flexibility for voltage adjustment in different grid conditions.
    Q What are the available low-voltage output options?
    The standard low-voltage output is 0.4 kV. However, according to customer requirements, the low-voltage output of the transformer can also be configured as 0.69 kV to suit specific industrial applications.
    Q What is the difference between the Standard Type and Enhanced Type dimensions?
    The Standard Type and Enhanced Type differ primarily in the dimension A (length). The Enhanced Type has a larger A dimension of 2400 mm compared to 1900 mm for the Standard Type, providing additional space for enhanced protection components or additional switchgear configurations. Other dimensions such as B, C, E, F, and H remain similar across both types for the same capacity range.
    Q What are the key electrical parameters of the load switch used in this transformer?
    The load switch is available in two rated current configurations: 315 A and 630 A, both rated at 12 kV. Key parameters include an impulse withstand voltage of 75 kV, power frequency withstand voltage of 42 kV (1 min), and short-circuit making currents of 31.5 kA and 40 kA respectively. The 315 A switch supports 2000 mechanical operations, while the 630 A switch supports 3000 mechanical operations.