Rubber Sheath Cables
The electric cables's line construction and electric resistance
| Nominal cross sec-tional area(mm²) |
Constr-uction |
20℃ conductor direct curren telectric resistance( Ω/km ) |
Nominal cross sec-tional area(mm²) |
Constr-uction | 20℃ conductor direct curren telectric resistance( Ω/km ) |
| 0.3 0.5 |
16/0.15 28/0.15 |
≤69.2 ≤39.0 |
16 25 |
126/0.40 196/0.40 |
≤1.21 ≤0.780 |
| 0.75 1.0 |
24/0.20 32/0.20 |
≤26.0 ≤19.5 |
35 50 |
276/0.40 396/0.40 |
≤0.554 ≤0.386 |
| 1.5 2.5 |
48/0.20 49/0.25 |
≤13.3 ≤7.98 |
70 95 |
360/0.50 475/0.50 |
≤0.272 ≤0.206 |
| 4 6 10 |
56/0.30 84/0.30 84/0.40 |
≤4.95 ≤3.30 ≤1.91 |
120 150 |
608/0.50 756/0.50 |
≤0.161 ≤0.129 |
YQ、YQW300/300V
| No of core x nominal cross scetional area(mm²) |
Insulation nominal thickness(mm) |
Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||
| min | max | YQ | YQW | |||
| 2x0.3 2x0.5 |
0.5 0.5 |
0.7 0.7 |
4.3 4.8 |
5.8 6.4 |
40 49 |
48 59 |
| 3x0.3 3x0.5 |
0.5 0.5 |
0.7 0.7 |
4.6 5.1 |
6.1 6.7 |
57 69 |
68 83 |
254IEC 53(YZ),245IEC 57(YZW),YZ,YZW300/500V
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness (mm) |
Two core | Three core | ||||||||
| Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||||
| min | max | YZ | YZW | min | max | YZ | YZW | ||||
| 0.75 1.0 |
0.6 0.6 |
0.8 0.9 |
6.0 6.6 |
8.2 8.8 |
70 84 |
84 101 |
0.9 0.9 |
6.5 7.0 |
8.8 9.2 |
85 105 |
102 120 |
| 1.5 2.5 |
0.8 0.9 |
1.0 1.1 |
8.0 9.5 |
10.5 12.5 |
110 153 |
130 183 |
1.1 1.2 |
8.6 10.0 |
11.0 13.0 |
136 194 |
155 288 |
| 4 6 |
1.0 1.0 |
1.2 1.3 |
10.6 11.8 |
13.7 15.1 |
234 312 |
260 375 |
1.3 1.4 |
11.3 12.6 |
14.5 16.1 |
287 385 |
320 430 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness(mm) |
Four core | ||||
| Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YZ | YZW | |||
| 0.75 1.0 |
0.6 0.6 |
0.9 0.9 |
7.1 7.6 |
9.6 10.0 |
116 125 |
139 150 |
| 1.5 2.5 |
0.8 0.9 |
1.1 1.2 |
9.6 11.0 |
12.5 14.0 |
180 242 |
210 280 |
| 4 6 |
1.0 1.0 |
1.3 1.4 |
12.7 14.0 |
16.7 17.9 |
396 530 |
430 570 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness(mm) |
Four core(3+2) | |||||
| Lord line core the x cut+connect the ground line core the x cut(mm²) | Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YZ | YZW | ||||
| 0.75 1.0 |
0.6 0.6 |
- - |
- - |
- - |
- - |
- - |
- - |
| 1.5 2.5 |
0.8 0.9 |
3x1.5+1x1 3x2.5+1x1.5 |
1.1 1.2 |
8.6 10.4 |
11.2 13.5 |
171 232 |
188 260 |
| 4 6 |
1.0 1.0 |
3x4+1x2.5 3x6+1x4 |
1.3 1.4 |
12.3 13.7 |
15.7 17.5 |
375 485 |
392 520 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness(mm) |
Five core(3+2) | |||||
| Lord line core the x cut+connect the ground line core the x cut(mm²) | Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YZ | YZW | ||||
| 0.75 1.0 |
0.6 0.6 |
- - |
1.0 1.0 |
8.0 8.5 |
11.0 11.5 |
140 157 |
160 173 |
| 1.5 2.5 |
0.8 0.9 |
3x1.5+2x1 3x2.5+2x1.5 |
1.1 1.2 |
10.5 12.5 |
13.5 15.5 |
201 294 |
230 320 |
| 4 6 |
1.0 1.0 |
3x4+2x2.5 3x6+2x4 |
1.3 1.4 |
14.1 15.7 |
17.9 20.0 |
425 590 |
457 630 |
245IEC 66(YCW),YC,YCW450/750V
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness (mm) |
Single core | Two core | ||||||||
| Nominal sheath thic-kness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
Nominal sheath thi-ckness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||||
| min | max | YC | YCW | min | max | YC | YCW | ||||
| 1.5 2.5 |
0.8 0.9 |
1.4 1.4 |
5.8 6.4 |
7.2 8.0 |
70 90 |
76 98 |
1.5 1.7 |
9.0 10.5 |
11.5 13.5 |
134 185 |
142 197 |
| 4 6 |
1.0 1.0 |
1.5 1.6 |
7.4 8.0 |
9.0 11.0 |
119 160 |
130 174 |
1.8 2.0 |
12.0 13.5 |
15.0 18.5 |
250 346 |
266 358 |
| 10 16 |
1.2 1.2 |
1.8 1.9 |
9.8 11.0 |
12.5 14.5 |
237 314 |
251 330 |
3.1 3.3 |
18.5 21.0 |
24.0 27.5 |
624 802 |
649 853 |
| 25 35 |
1.4 1.4 |
2.0 2.2 |
12.5 14.0 |
16.5 18.5 |
452 587 |
475 605 |
3.6 3.9 |
25.0 27.3 |
31.5 34.6 |
1137 1522 |
1189 1586 |
| 50 70 |
1.6 1.6 |
2.4 2.6 |
16.5 18.5 |
21.0 23.5 |
805 1086 |
828 1116 |
4.3 4.6 |
31.8 35.8 |
40.0 45.1 |
2005 2620 |
2100 2704 |
| 95 120 150 |
1.8 1.8 2.0 |
2.8 3.0 3.2 |
21.0 23.5 26.0 |
26.0 28.5 31.5 |
1403 1687 2082 |
1440 1725 2115 |
5.0 - - |
40.2 - - |
51.0 - - |
3304 - - |
3412 - - |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness (mm) |
Three core | Four core | ||||||||
| Nominal sheath thic-kness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
Nominal sheath thi-ckness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||||
| min | max | YC | YCW | min | max | YC | YCW | ||||
| 1.5 2.5 |
0.8 0.9 |
1.6 1.8 |
9.6 11.5 |
12.5 14.5 |
170 230 |
180 245 |
1.7 1.9 |
10.5 12.5 |
13.5 15.5 |
212 298 |
225 308 |
| 4 6 |
1.0 1.0 |
1.9 2.0 |
13.0 14.5 |
16.0 20.0 |
330 441 |
352 465 |
2.0 2.3 |
14.5 16.5 |
18.0 22.0 |
408 566 |
430 596 |
| 10 16 |
1.2 1.2 |
3.3 3.5 |
20.0 22.5 |
25.5 29.5 |
789 1056 |
825 1105 |
3.4 3.6 |
21.5 24.5 |
28.0 32.0 |
854 1147 |
884 1187 |
| 25 35 |
1.4 1.4 |
3.8 4.1 |
26.5 29.5 |
34.0 38.0 |
1528 2207 |
1588 2297 |
4.1 4.4 |
29.5 33.0 |
37.5 42.0 |
1953 2453 |
2055 2643 |
| 50 70 |
1.6 1.6 |
4.5 4.8 |
34.5 39.0 |
44.0 49.5 |
2701 3508 |
2805 3612 |
4.8 5.2 |
38.0 43.0 |
48.5 54.5 |
3445 4510 |
3550 4690 |
| 95 120 150 |
1.8 1.8 2.0 |
5.3 5.6 6.0 |
44.0 47.3 52.0 |
54.0 60.0 66.0 |
4581 5500 6854 |
4731 5650 7014 |
5.9 6.0 6.5 |
49.0 53.0 58.5 |
60.5 65.5 74.0 |
5958 7100 8919 |
6120 7280 9019 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness (mm) |
Fourcore (3+1) | |||||
| Lord line core the x cut+connect the ground line core the x cut(mm²) | Nominal sheath thickness (mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YC | YCW | ||||
| 1.5 2.5 |
0.8 0.9 |
- 3x2.5+1x1.5 |
- 2 |
- 11.9 |
- 15.2 |
- 290 |
- 305 |
| 4 6 |
1.0 1.0 |
3x4+1x2.5 3x6+1x4 |
2.0 2.2 |
13.6 15.2 |
17.4 19.4 |
405 531 |
425 560 |
| 10 16 |
1.2 1.2 |
3x10+1x6 3x16+1x6 |
3.0 3.5 |
19.4 22.3 |
24.6 28.3 |
870 1187 |
924 1237 |
| 25 35 |
1.4 1.4 |
3x25+1x10 3x35+1x10 |
4.0 4.0 |
27.3 29.6 |
34.4 37.3 |
1743 2119 |
1794 2199 |
| 50 70 |
1.6 1.6 |
3x50+1x16 3x70+1x25 |
5.0 5.0 |
35.4 39.6 |
44.7 49.8 |
3062 3665 |
3162 3765 |
| 95 120 150 |
1.8 1.8 2.0 |
3x95+1x35 3x120+1x35 3x150+1x50 |
5.0 5.0 5.0 |
43.8 46.7 51.3 |
55.1 58.8 64.5 |
4908 5820 6760 |
5008 5990 6820 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness(mm) |
Five core | ||||
| Nominal sheath thickness(mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YC | YCW | |||
| 1.5 2.5 |
0.8 0.9 |
1.8 2.0 |
11.5 13.5 |
15.0 17.0 |
247 359 |
267 379 |
| 4 6 |
1.0 1.0 |
2.2 2.5 |
16.0 18.0 |
19.5 24.5 |
520 711 |
550 750 |
| 10 16 25 |
1.2 1.2 1.4 |
3.6 3.9 4.4 |
24.0 27.0 32.5 |
30.5 35.5 41.5 |
1225 1602 2380 |
1275 1662 2475 |
| Nominal cross sec-tional area(mm²) |
Insulation nominal thickness (mm) |
Five core (3+2) | |||||
| Lord line core the x cut+connect the ground line core the x cut(mm²) | Nominal sheath thickness (mm) |
Maixmum limit average(mm) |
The tests the weight(kg/km) |
||||
| min | max | YC | YCW | ||||
| 1.5 2.5 |
0.8 0.9 |
3x1.5+2x1 3x2.5+2x1.5 |
2.0 2.0 |
11.5 13.5 |
13.0 15.0 |
240 332 |
252 352 |
| 4 6 |
1.0 1.0 |
3x4+2x2.5 3x6+2x4 |
2.0 2.2 |
15.0 18.0 |
15.0 18.0 |
450 589 |
470 628 |
| 10 16 |
1.2 1.2 |
3x10+2x6 3x16+2x10 |
3.0 3.5 |
23.5 27.5 |
25.5 30.0 |
995 1306 |
1045 1406 |
| 25 35 |
1.4 1.4 |
3x25+2x16 3x35+2x10 |
4.0 4.0 |
32.5 35.5 |
35.0 38.0 |
1988 2367 |
2068 2467 |
| 50 70 |
1.6 1.6 |
3x50+2x25 3x70+2x25 |
5.0 5.0 |
42.5 47.5 |
45.5 51.0 |
3454 4430 |
3564 4562 |
| 95 120 150 |
1.8 1.8 2.0 |
3x95+2x50 3x120+2x70 3x150+2x70 |
5.0 5.5 5.5 |
53.5 59.5 62.5 |
57.0 63.0 66.0 |
5730 7100 8224 |
2880 7280 8394 |
Note: The four core eterprise standards for a smal three five three two small core structure of the DC resistance and grounding wire cross section corre sponding with the main line of the same type.
Model and name
| Model | Name | Usage |
| YO,YQW | Soft electric cable of light set | Electrical equipment and tools for mobile light |
| 245IEC53(YZ) 245IEC57(YZW) |
Soft line of common strength | Electrical equipment and tools for the various mobile |
| YZ、YZW | Soft electric cable of mcoium-sized set | Electrical equipment and tools for the various mobile |
| 2451EC66(YCW),YC.YCW | Heavy type set soft electric cable | Electrical equipment on all mobile and can withstand greatermechanical forcing |
Applying terms
● The product applies to the signal and control circuits for supporting the lift lines used.
● Reted voltage chaaracteristicsuse Uo/ for 450/750V,300/500V and 300/300V Iong cables should not be allowed to work more than 60°C.
● "W" the type parties living the electric cable to have to bear the weather with certainly bear the oil function, proper in outdoor or get intouch with dirty situation usage of oil.